FIRAS Fire Stopping Accreditation

Our Engineered Solution for Damaged Loft Fire Breaks & Spandrel Panels

How we deliver a compliant, certified result
Your Safety, Our Mission

Why this matters

Compartmentation in roof spaces is critical. In semi-detached and terraced homes, the dividing construction in the loft must resist fire spread long enough for occupants to escape and for the fire service to intervene. When those fire breaks or spandrel panels are missing, poorly installed, uncertificated, or have suffered water/moisture damage, the compartment line is compromised—and so is compliance.

Advanced Fire & Security provides a fully certificated, FIRAS-installed solution to restore compartmentation performance and demonstrate compliance, with a tested 60-minute (1-hour) fire rating and built-in thermal and acoustic performance appropriate to the application.

Firestops large wall and floor openings – with multiple pipes and cables.

A complete and fully documented firestop system with proven performance.

What is FIRAS?

FIRAS is a UK third-party certification scheme for installers of passive fire protection. Contractors are assessed for technical competence, quality management, on-site workmanship, and surveillance. A genuine FIRAS contractor can issue FIRAS Certificates of Conformity for completed works, providing traceable evidence to clients, building control, insurers, and fire risk assessors that systems were installed in accordance with the relevant tested designs.

What you get with a FIRAS contractor:

  • Competency-audited supervisors and installers

  • Installation to tested and listed system details (not improvised “like-for-like”)

  • Documented QA, materials traceability, photographs, and calibration records

  • Unique certification per plot/area, lodged and verifiable

Typical problems we resolve

  • Failed surveys (missing or incomplete loft fire breaks / spandrel panels)

  • Un-certificated historic work with no evidence of tested details

  • Water or moisture-damaged boards/insulation reducing fire, thermal, and acoustic performance

  • Gaps at eaves, ridges, party wall junctions, and service penetrations

  • Improper materials (e.g., non-rated foam, non-A1/A2 boards, or single-layer plasterboard where a tested build-up is required)

Our engineered replacement syste

We install a tested, non-loadbearing compartment panel designed for loft dividing lines between dwellings (the “party” or compartment wall/line within the roof space). The assembly is selected from a manufacturer’s tested specification to provide:

  • Fire resistance: 60 minutes integrity and insulation (1-hour rating) when installed to the tested detail

  • Thermal performance: mineral wool core and airtight finishing to help limit heat loss and mitigate condensation risk

  • Acoustic performance: high-density mineral wool and sealed linings to reduce sound transfer across the party line

Where this is used

  • Semi-detached and terraced dwellings with shared lofts/attics

  • Timber, masonry, or mixed party-line constructions requiring a 60-minute compartment in the roof space

  • Remedial works following surveys by housing associations, insurers, building control, or fire risk assessors

Project

  1. Survey & Scope – Inspection of the existing loft line, defects, and moisture damage

  2. Method Statement & RAMS – Safe access via loft hatch, dust control, waste removal

  3. System Selection & Manufacturer Liaison – Chosen tested detail to 60-min rating

  4. Installation – Removal of failed panels, reinstallation of certified system through loft hatch with minimal disruption

  5. Thermal & Acoustic Considerations – Correct density mineral wool, airtight finishing, maintained ventilation strategy

  6. Quality Assurance & Certification – Photographic records, QA forms, FIRAS certification on completion

Compliance

  • The goal is to restore compartmentation at the roof/loft party line in line with the project’s required period (typically 60 min).

  • We install a tested system with documented fire resistance and appropriate thermal/acoustic characteristics.

  • Works are carried out by a FIRAS-certified contractor, and Certificates of Conformity are issued on completion.

  • Our documentation supports Building Regulations fire safety objectives (compartmentation) and provides auditable evidence for duty-holders and assessors.

Next steps

  1. Send your survey or fail report (photos and addresses help).

  2. We’ll propose the tested system, programme the work, and price it clearly.

  3. We install under FIRAS, complete QA, and issue FIRAS certification upon handover.

Talk to us

Advanced Fire & Security
Fire stopping & compartmentation specialists (FIRAS-certified)
Cornwall • Devon • Somerset • Dorset • Bristol and surrounding areas